Re: Updating C7000 OA Firmware from cli and mounted custom SPP

$
0
0
It seems the OA firmware update function is not in the Enclosure Firmware Management Commands section of the OA CLI Guide. It's in the previous section titled Enclosure Management Commands. Specifically, the cmd is UPDATE IMAGE FW_ISO that the manual shows usage as: UPDATE IMAGE {[FORCE} FW_ISO url | SYNC} But specifying a url doesn't work - invalid cmd. Seems to use the url specified with the SET FIRMWARE MANAGEMENT URL cmd in the next section of the manual. UPDATE IMAGE FW_ISO causes the OA FW to be updated and the OA to reboot. It didn't do the Interconnects (6125g switch or IB FDR 4x switch) firmware, but there are no fw updates for these components in my Custom SPP. Don't know if it would have updated them if updates were present.