Re: c7000 enclosure Visio Stencil

Thank you very much it was exactly what I needed

View Article


Re: ilo AD scriping?

Hi -- The "Mod_Directory.xml" part of the RIBCL scripting toolkit will configure an ILO to use AD for user lookups and Mod_Schemaless_Directory.xml lets you set up groups (typically with different...

View Article


Re: Enclosure Inadequate Power To Power On: Not Enough Power

Hi, Gerardo.How do you solve this issue. I have a C3000 Enclosure with 2 clusters:ClusterA1: 4 BL460c G8Cluster B: 2 BL460c G9 with 1 BL460c G7My BL460 G7 is showing that same message, but it still on,...

View Article

BladeCenter C7000 make good use

Hello everyone,I have 4 BladeCenter with many blades and modules (Ethernet, SAN, SAS, iLO, but no VC-Flex).I would like to use this BladeCenter at its most. I do not know what I can do with it. Do you...

View Article

Communication with Active Onboard Administrator Lost

I am trying to update the interconnect module currently on my C7000 blade system but the OA always loses connection while in the middle of it. I have two OA (4.60) and two interconnect modules Flex-10...

View Article


Re: Communication with Active Onboard Administrator Lost

HelloPlease post vcsu log, also I assume you are not connectedOn VC to do update ?ThanksJY

View Article

Re: Communication with Active Onboard Administrator Lost

I cannot do the update by VC only from VCSU (from what I understand) so I do not understand your question. What log ? There is no log for this as far as I am aware, It only stops when I shutdown VCSU....

View Article

Re: Communication with Active Onboard Administrator Lost

How can you update vc ?Using VCSU utilily right ?So VCSU utility created logs for all step of updateThese logs are located in vcsu directoryJY

View Article


Image may be NSFW.
Clik here to view.

Re: Communication with Active Onboard Administrator Lost

VCSU DirectoryThese are the only files in the directory, I have no idea what logs you are speaking of.All other logs are in the C:\Users\user\AppData\Local\Temp folder and named vcsu-### No log was...

View Article


Re: Communication with Active Onboard Administrator Lost

That is I'm looking for also confirm you are not connected to VCTo do update ?JY

View Article

Re: Communication with Active Onboard Administrator Lost

I do not understand what you mean by "connected to VC" I am using VCSU because it is not possible to update interconnect module firmwares from the Virtual Connect Manager. I can connect to the Manager...

View Article

Re: Communication with Active Onboard Administrator Lost

Are you connected directly to oa ethernet portTo do update or somewhere on the network and passing thru VCTo reach themThat is my questionJY

View Article

Image may be NSFW.
Clik here to view.

Re: Communication with Active Onboard Administrator Lost

Always testing I am. Here is what happens when I am connected to the web gui (OA and VC) at the same time as the VCSU : I then go to the standby OA's web gui (becasue I do not have access to the real...

View Article


Re: Communication with Active Onboard Administrator Lost

I am on the same network... ? I connect through the ip address and everything works until the ip stops working. That ip is the ip of the active OA that is connected to a switch with a RJ-45 cable.... I...

View Article

Re: Communication with Active Onboard Administrator Lost

I would first check for duplicated IP addresses.Depending on the netmask used the components are/are not on the same network. From your logs:Unable to communicate with given IP 192.168.1.129OA found at...

View Article


Re: Communication with Active Onboard Administrator Lost

The netmask is 255.255.254.0 for all of them. The network is 192.168.0.0/23. There is no duplicate that I am aware of.192.168.1.129 and 192.168.1.123 are the OA (standby or active depending on who lost...

View Article

Re: Communication with Active Onboard Administrator Lost

How about the IP of the VC module(s)? Sometimes it help sto reset the VCM, from CLI within the VC module you do reset vcm  

View Article


Re: Communication with Active Onboard Administrator Lost

The ip of the module is also in the same network/netmask but follows the Active OA. If one does not work the other does not work either and it will only come back if I change the Standby OA to Active....

View Article

Re: Communication with Active Onboard Administrator Lost

I would try this now:- pull both OA modules- re-seat the OA tray- insert the OAs, first the primary, wait until it is up, then the second.

View Article

Re: Communication with Active Onboard Administrator Lost

Took both OA out, took out the OA bay and put it back in, than re-added the OAs inside it primary first, waited for it to set and then added the second. In addition to that I changed their adresses to...

View Article