Re: BL460c Gen10 - Memory Configuration Reccomendation

Hello,  Optimal memory performance is achieved when the system is configured with a fully homogeneous and balanced memory configuration.Each processor socket contains six memory channels that support...

View Article


Smart Array P410 Memory

Mod : Post moved to ProLiant Servers

View Article


Re: Powershell cmdlet to install a CA certificate on c7000 Onboard Administrator

Use the following cmdlet to import SSL certificate to OAStart-HPOACertificateDownload -Connection $connection -Type OA -URL ftp://10.12.23.17/cer_southking/ldap_southking.cer -Bay <<Bay number of...

View Article

Get Connected to HPE – let us worry about your technology so you can focus on...

Unlock all the benefits of your technology investment by connecting your products to HPE. With 24x7 monitoring and pre-failure alerts, you'll solve problems faster and minimize downtime. And should a...

View Article

Re: Powershell cmdlet to install a CA certificate on c7000 Onboard Administrator

It's working now - thanks for the valuable advice!

View Article


performance c7000 internal

Dear all,we have a c7000 enclosure with bl 460c gen9 blades which are esxi hostsnow the issiue is that copy data  from vm to vm what should stay in the same enclosure has only 80 Mb performancecopy...

View Article

Blades not powering up

First I want to say I am not a company. I am just a guy playing around with some old equipment.I have an old C7000 with a couple of 460 G7's. I initially set everything up with two 3120X's and...

View Article

Re: Blades not powering up

 wrote:First I want to say I am not a company. I am just a guy playing around with some old equipment.I have an old C7000 with a couple of 460 G7's. I initially set everything up with two 3120X's and...

View Article


Re: Blades not powering up

 wrote:irtual Connect Flex-10 Ethernet Modules do support 10GbE and more options such as splitting a flex-NIC into 4 ports of varying speed to equal 10Gbmaybe a defective 6120?  Mismatched firmware...

View Article


Re: Blades not powering up

I am getting this message in the system log for all of my blades but the only thing I can find concerns OA firmware 4.6 that states to upgrade to 4.7 but I am on 4.7OA: Device in bay #2 power delayed...

View Article

Re: Blades not powering up

Virtual connect mode was still on. Solution was to go underEnclosure Settings -> Reset Factory Defaults ->  Clear VC ModeOnce vc mode was disabled the blades powered up.

View Article

Re: performance c7000 internal

Hello,The following white paper may provide...

View Article

c7000 - mix of different OA Hardware Revisions possible?

Hello,currently we got a 456204-B21 Open Administrator (HW Revision "B2") in our productive c7000. Next to Virtual Connect.We also got a spare 407296-001 Open Administrator in one of our retired...

View Article


Re: c7000 - mix of different OA Hardware Revisions possible?

Hi ,As per your query I found below information which can be helpful."The part number for HP Onboard Administrator is displayed as part number 407296-001 on the HP BladeSystem c7000 Enclosure Onboard...

View Article

C7000 test setup

Hi alli have a c7000 im using as a test bed. i need to test the VC-FC 4Gb module and wondered what the simpliest but most effective way to test one would be.would it be possible to connect a VC-FC...

View Article


Re: c3000 Sharing storage across blades

Hello,As the Local Storage of each blades are tied to its own servers, you cannot share the Drive space to pool together, unless its a Blade Storage server.If Blade Storage server is not a possible...

View Article

Re: Error: Power loss due to overheating. Attempting to restore power Server:...

Hello,To prevent possible server Blade overheating, always populate each processor socket with a processor socket cover and a heatsink blank or a processor and a heatsink.Ensure Proper Blanks are...

View Article


Re: C7000 test setup

Hello,I hope the VC-ENET / FlexFabric Modules are installed on the Primary two interconnect slots of the enclosure.We strongly suggest using the 4GB VC-FC with conjuction to a VC ENET/Fabric Modules on...

View Article

Re: C7000 test setup

HiThanks for you replyyes im using the Vc-enet aswell.the one thing i wanted to confirm is can i configure it so the 2x blades with dual FC ports be mapped to 2x ports on the VC-Fc card? Thanks

View Article

Network problem

Hi alli have some problem with networking.We have two hp blade systems c3000 and i want  to move two bays to uper one, when i do this, machine is working fine but id doesn't have network, im also...