Re: ILO5 Firmware update for Gen10 Blades via Onboard Admistrator
Hi ,This seems like a concurrent update limitation of OA.Based on my understanding firmware update is two step process:Downloading the image, andFlashing the image.While doing firmware update for...
View Article2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
Dear Community Members,I have two decent 9 years old C7000 chassis with OA version 3.30. One chassis is equipped with 8 x BL460 G1 blades, second chassis is equipped with 8 x BL680 G5 respectibely. VC...
View ArticleSmart array fw update
Hi AllI want update smart array firmware on hp blade on enclosure c7000 running solaris 10 on it. Kindly guide me complete procedure to update.Thanks
View ArticleSmart array firmware upgrade
Smart array fw updateHi AllI want update smart array firmware on hp blade gen 8 on enclosure c7000 running solaris 10 on it. Kindly guide me complete procedure to update.Thanks
View ArticleRe: 2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
Some illustrations to the issue:Please find below videos with LED from fully faulty Chassis 1 with BL680 G5 and Chassis 2 with partially faulty BL460 G1...
View ArticleRe: ILO5 Firmware update for Gen10 Blades via Onboard Admistrator
Hi,I tried 4 BL460s only and it still died. And because of change management, I cannot just upgrade the OA. Neither do I have time to muck about trying different versions etc. This should just work,...
View ArticleRe: ILO5 Firmware update for Gen10 Blades via Onboard Admistrator
Hi,Certainly it should work, future firmware should fix it.However,I believe you should raise a support case with HPE to investigate this issue.Regards,Sudhir
View ArticleRe: Smart array firmware upgrade
Hello, Please share the complete server model detail as well as complete OS information.Regards,
View ArticleRe: Smart array fw update
HiHPE ProLient Gen6 onward servers, you can use HPE SPP (HPE Service Pack for ProLiant) to update Smart Array controller firmware.Initiating SPP offline deployment:1. Download latest SPP depending on...
View ArticleVirtual Connect - How to Make Virtual Network Assigned in the Same LOM 1-A...
We have C7000 blade, with two node installed. In network side, one virtual connect (VC) was installed. We already created some virtual network in VC Manager to integrate with network environment. Then...
View ArticleRe: Certificate/Letters of Volatility
Hello,HPE customers must request a Statement of Volaility (SoV) from your HPE sales representative or HPE point-of-contact who can obtain an SoV for you. You will receive and automated message from...
View ArticleRe: HP C7000 AC redundant mode question
To do it without powering off the Blade.First set the Power mode to Not Redundant: or Power Supply Redundant: it is in the Power Management page of the OA. Disable Dynamic Power. It is in the same...
View ArticleRe: HP C7000 AC redundant mode question
"In N+N AC Redundant power mode, a minimum of two power supplies is required. N power supplies provide power and N provide redundancy, where N can equal 1, 2, or 3.The Onboard Administrator reserves...
View ArticleCan't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
I have recently purchased two BL860c i2 blades and a BL860c i1 blade in a c3000 chassis. These are Itanium and are running HPUX 11i v3. The two BL860c i2 blades have an embeded 10Gig network card...
View ArticleRe: Can't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
I had the network guys check the 6509 Cisco switch and they do not see MAC addresses for my HP systems, but they do for the Solaris systems. So that tells me I have a layer two issue. Hmmm..
View ArticleRe: Can't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
> [...] 192.168.5.26 [...]> [...] 192.168.4.26 [...]> [...] 192.168.16.180 [...] What's the subnet mask for these interfaces? Around here (/24),each would be on its own subnet.
View ArticleRe: Can't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
Maybe the blade was left in virtual connect mode, but you don't have VC.Worth to try a "clear vc mode",...
View ArticleRe: Can't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
192.168.5.x/24192.168.4.x/24192.168.16.x/22The first two are just "test" networks that I'm using to verify 10Gig NIC functionality. The 192.168.16.x/22 network is a lab network on the 1gig interface....
View ArticleRe: Can't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
Thank you for the reply. I went into the OA and I found that the VC mode is set to disabled. So I am guessing that this isn't it.
View ArticleRe: Can't get 10Gig networking working with BL860c i2 blade in a c3000 chassis
A single blade in non-VC mode looks like this (without mezzanine):# ioscan -ClanH/W Path Class Description=================================================================0/0/0/3/0/0/0 lan HP PCIe 2-p...