Re: ILO5 Firmware update for Gen10 Blades via Onboard Admistrator
Hi , This seems like a concurrent update limitation of OA.Based on my understanding firmware update is two step process:Downloading the image, andFlashing the image.While doing firmware update for...
View Article2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
Dear Community Members,I have two decent 9 years old C7000 chassis with OA version 3.30. One chassis is equipped with 8 x BL460 G1 blades, second chassis is equipped with 8 x BL680 G5 respectibely. VC...
View ArticleSmart array fw update
Hi AllI want update smart array firmware on hp blade on enclosure c7000 running solaris 10 on it. Kindly guide me complete procedure to update.Thanks
View ArticleSmart array firmware upgrade
Smart array fw updateHi AllI want update smart array firmware on hp blade gen 8 on enclosure c7000 running solaris 10 on it. Kindly guide me complete procedure to update.Thanks
View ArticleRe: 2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
Some illustrations to the issue:Please find below videos with LED from fully faulty Chassis 1 with BL680 G5 and Chassis 2 with partially faulty BL460 G1...
View ArticleRe: ILO5 Firmware update for Gen10 Blades via Onboard Admistrator
Hi,I tried 4 BL460s only and it still died. And because of change management, I cannot just upgrade the OA. Neither do I have time to muck about trying different versions etc. This should just work,...
View ArticleRe: ILO5 Firmware update for Gen10 Blades via Onboard Admistrator
Hi,Certainly it should work, future firmware should fix it.However,I believe you should raise a support case with HPE to investigate this issue.Regards,Sudhir
View ArticleRe: Smart array firmware upgrade
Hello, Please share the complete server model detail as well as complete OS information.Regards,
View ArticleRe: Smart array fw update
HiHPE ProLient Gen6 onward servers, you can use HPE SPP (HPE Service Pack for ProLiant) to update Smart Array controller firmware.Initiating SPP offline deployment:1. Download latest SPP depending on...
View ArticleVirtual Connect - How to Make Virtual Network Assigned in the Same LOM 1-A...
We have C7000 blade, with two node installed. In network side, one virtual connect (VC) was installed. We already created some virtual network in VC Manager to integrate with network environment. Then...
View ArticleRe: Certificate/Letters of Volatility
Hello,HPE customers must request a Statement of Volaility (SoV) from your HPE sales representative or HPE point-of-contact who can obtain an SoV for you. You will receive and automated message from...
View ArticleRe: 2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
You have mentioned that all the devices were removed & reinserted in both the Chassis. Not sure if the OA Tray/Sleeve was removed & reseated. If not done, this is highly recommended.OA...
View ArticleRe: Smart array firmware upgrade
HiAs I mentioned details furthermore server model is HPE Blade 460c gen 8 and solaris 10 is running on it.Your response is highly appreciatedThanks
View ArticleRe: 2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
As you can notice from intial post, I already brought OA from different Chassis, which had different OA version, so extraction and insertion of OA modules was performed several times at least. I did...
View ArticleRe: 2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
Both the Enclosures may require a field service with or without part replacement. Hence, we recommend to contact the HPE Support team to raise a support ticket for further assistance. There are...
View ArticleRe: Smart array firmware upgrade
Hello,Follow the below link to update the firmware.If the SA controller firmware is very old with the latest...Do not update the latest firmware directly. you have to update the firmware incremental....
View ArticleRe: Virtual Connect - How to Make Virtual Network Assigned in the Same LOM...
There is a limitation that you can’t map the same VLAN onto two different FlexNICs from the same LOM.The FlexNICs are subdivide as LOM 1:a, LOM 1:b, LOM 2:a, etc. And up to four FlexNICs are presented...
View ArticleRe: 2 x C7000 stop recognize BL680 G5 and BL460 G1 after OA Upgrade
Please perform the below steps:a. Power Cycle the complete c7000 Enclosure.b. I understand OA modules were Swapped between enlcosures, however There is a OA Tray which Holds the OA MOdules, Please...
View ArticleC-7000 ilo3 login problem
Hello,I have a BL680c in a C-7000 enclosure. The server comes up "degraded" but OK/Yellow in the health page on the little lcd screen on the front. The SUV cable has no signal/power on the USB or SVGA...
View ArticleAgen Bola NOVA88 Indonesia
Seperti situs nova88 Indonesia kita kupas sebelumnya, bahwa tersedia tidak keuntungan sanggup kalian. Dan untuk sadar apa saja deviden yang peroleh, maka segera kalian lihat deviden nova 88 bet login....
View Article