Re: C7000 blade system problem

Looks like you still use the wrong IP address for your PC, try netsh interface ipv4 set address name="Local Area Connection" static 169.254.1.254 255.255.255.0 from a CMD window, check with "ipconfig"...

View Article


Re: C7000 blade system problem

I tried that command from the cmd box, I had to run the cmd box as admin, it accepted the command, Tried IPCONFIG /ALL  and still nothing. I have not got 1 responce from the interlink port in 2 days....

View Article


Re: C7000 blade system problem

The interconnects arebay1: Brocade (B-series) fibre channel switchbay3: 1Gb ethernat pass-tru (direct connection from the blade NICs to the module RJ-45 jacks)bay5: Cisco network switch The blades are...

View Article

Re: C7000 blade system problem

Since the OA looks like working, I would try the serial connection again.Take a null modem cable, connect it between the active OA and your PC, start putty, select serial, type in 9600 as speed and...

View Article

Re: C7000 blade system problem

dont know if you missed my post earlier Torsten , but i got to the log in screen when i plug the network cable into the OA module itself, NOT the interlink connection Both of them appear when i connect...

View Article


Image may be NSFW.
Clik here to view.

Re: C7000 blade system problem

I still think the system is OK and at least the serial connection method will work. However, another workaround.Keep ping "192.168.1.2" which is obviously an ILO of one of the blades.Pull blade by...

View Article

Re: Blade System Module

Hi Can I use a HP 1/10Gb Virtual Connect Ethernet Module - expansion module - 8 ports to connect the bladesystem to a switch or firewall with RJ45 connections? Thaks for the advice.

View Article

HPE Synergy Community Forum is now live!!!

The first platform architected for Composable Infrastructure, HPE Synergy is now available and shipping worldwide.  As the first solution of its kind, HPE realizes that there can be significant...

View Article


Re: Blade System Module

HiCan I use the HP 1/10Gb Virtual Connect Ethernet Module - expansion module - 8 port just to give my blade system another 8 RJ45 connections to a LAN?I don't want to purchase the wrong module so any...

View Article


Re: Accessing Blade Server

Usually the OA in a C7000 is redundant, so if the primary somehow fails you can use the standby OA.However, once the blades are up and running, you can access the OS via the configured networks thru...

View Article

Re: Blade System Module

helloshall you HPE reference (product number)also a litle picture of what you want to dothanksJY

View Article

Re: C7000 blade system problem

Hello again TorstenToday i recieved a  replacement  OA 'sleeve' module from Germany that was sold as 'tested  and working'Im afraid it has made no difference. You were correct in your assumption of it...

View Article

Re: C7000 blade system problem

update-I just plugged in 2 blades and turned on the serverAfter a while they both start flashing a red led. It is the second red LED down from the top. It has an icon like a soundwave.After more...

View Article


Image may be NSFW.
Clik here to view.

Re: C7000 blade system problem

>> I dont understand networking at all. This makes me think the issue could be user caused ... sorry ;-) If the IP address of your laptop doesn't fit the C7000 network settings, it cant work.We...

View Article

Re: C7000 blade system problem

I now now have 2 power supplys connected - the blades connected are no longer flashing red lights - so that problem is fixedBut still no data from the laptop portI have done everything you have said...

View Article


Re: C7000 blade system problem

If the OA network settings are unknown, the first step would be to connect the OA/iLO port to a network with a DHCP server. You would then look at the DHCP server logs to see if it is requesting an...

View Article

Re: C7000 blade system problem

Decided to use ipconfig/all repeatadily as the m,achine boots.the ip address appears as the server is booting - it came up in ipconfig/all  as 169.254.183.186. It is the first time I have seen it. but...

View Article


Re: C7000 blade system problem

The 169.x.x.x is know as the link local address space an OS may assign when it cannot access a DHCP server.  Your options are to buy a new LCD panel, or use a serial null modem cable between a pc and...

View Article

Re: C7000 blade system problem

get the serial null modem cable, you'll need it anyway to get the password.

View Article

Re: C7000 blade system problem

i will try torsten i already made a null modem cable, plugged it in and got nothing i am sad for asking so much advice and help , could you send the pinouts of such a cable - ive already tried but...

View Article