Re: HPE C7000 - Packet Loss to Bay iLO Addresses
1. Reseat OA tray(Physically pull the OA tray from the enclosure and then plug it back in). 2. Verify OA event log and if you found “Kernel: Network flood sources” messages then please segregate...
View ArticleVCFC 4GB - B21
HiAre there any known issue with VC manager software V4.01 when using the -B21.im having issues when running the setup for the VC manager.i have tried differant browsers and o/s but still got problems....
View ArticleRe: VCFC 4GB - B21
Please share the Full product number (b21 ) of thr VC module. so we may check for any known issuesAlso share the below information1. Any error screenshots reporting the issue2. what is the OA firmware...
View ArticleRe: VCFC 4GB - B21
Hi409513-B21 - 4.01OA F/W 4.85Basically it freezing on the domain setup screen, on general settings.i have tried a differant vc manager cards and differant VCFC 4gb cards.this doesnt happen using the...
View ArticleRe: Connecting to Blade9.... KVM Console
HI,Please provide the below details1. exact Model of the server2. Model of the KVM which you are using to connect.3. How exaclty the connection is made?4. Exact error message when connecting to...
View ArticleRe: VCFC 4GB - B21
i beleive the issue here is , there is a huge gap between the OA FW (4.85) and VC FW(4.01) . This is is known to cause stability issues with the performance. This explains the absense of this issue on...
View ArticleRe: VCFC 4GB - B21
problem being the VCFC 4GB -B21 stopped being supported after 4.01.maybe ill have to downgrade the OA.
View ArticleRe: VCFC 4GB - B21
Hi , Yes , kindly procees with the downgrade.If the issue persists even after the downgrade, Please log a support case with HPE so we may investigate this...
View ArticleRe: VCFC 4GB - B21
HiDowngraded the OA firmware to 2014 but the VC manager setup hangs when trying to setup the network, gets stuck at 4%.
View ArticleRe: VCFC 4GB - B21
Hi Kindly log a support case with HPE so we may investigate this further.you may log the case by accessing the below link:https://internal.support.hpe.com/portal/site/hpsc/scm/submitCase
View ArticleBest Baby Safety Gates Ever
When you are on a fundamental floor and your tyke is investigating, stairs going up can be as a lot of an issue. It's simple for them to buy baby gate for bottom of stairs the stairs really busy...
View ArticleRe: C7000 with BL460 Gen & Gen10 ILO Media extremely slow
Same issue on DL360P Gen10 !!! Virtual drive mounted with Java Remote Console. Installing XenServer took 45 minutes !!! On old G9, in takes 5 minutes... We have tested forcing 100FD on both server and...
View ArticleConverting c7000 from 3 phase to single phase power
I have a need to convert 2 c7000 chassis from three phase input power to singe phase. My reseach tells me that this can be done simply by swapping the power module and then enter command 'Set...
View ArticleSpp - preventing reboot
Hi, I am deploying 100+ blades utilising SCCM. The SPP is copied locally and executed locally as part of the task sequence.Since moving to SPP 1806 and newer i have found that utilising...
View Articleconnection with DS8886
Which is the firmware for the HP B-series 8/12c Blade System SAN Switch to connect to IBM DS8886 storage
View ArticleRe: Spp - preventing reboot
Hi SPP upated always required reboot its very recommaded you cont stop the reboot you can delay reboot as per convienent Reboot delay Syntax --reboot_delay timeout_in_secs (Linux) /reboot_delay...
View ArticleHP Proliant ML350 G6
Hello users! I have one problem with array controller P410i , notify error accelerator (status:disabled, battery status:ok, read errors:0, write errors:0, error code: read failure.Model Smart array...
View ArticleProblem HP Proliant ML350 G6 and controller Smart array P410i
Hello users! I have one problem with array controller P410i , notify error accelerator (status:disabled, battery status:ok, read errors:0, write errors:0, error code: read failure.Model Smart array...
View ArticleIssues with new 4gb fiber switch module
Purchased a new Cisco fiber switch module, when I was insert it into a c7000 enclosure the blade gets initialized but then goes to all amber lights for the port status lights. When I insert a spf, I...
View Article